Eeti Egalax I2c Programming Manual

Posted By admin On 20/06/18

Hello, I continue investigate the comunication. I have a conclusion but I need the confirmation of the experts. Dear Tsuneo, Thank you very much for your help. I think without your help I can´t finish this project. I understand all that you writte at the anterior post.

Eeti Egalax

Driver download from eGalaxTouch calibration does not work at 12. Why I2C designed to work with pull-up resistors and. Driver Details. For more downloads. This package provides the application for EETI eGalax EMPIA Multi-touch Touchscreen and. The use of the program is also.

Egalax Touch Driver

I think the configuration and the commands are the correct, but, I have a problem with 'USBHostGenericTxIsBusy(deviceAddress)'. We never exit for the states 'DEMO_STATE_WAITING_XXX'. I think that the variable 'gc_DevData.flags.txBusy' never is 0. If I find in all files of my proyect and I never asign 'gc_DevData.flags.txBusy=0'. At 'void USBHostGenericTasks( void )' we have 'gc_DevData.flags.txBusy = 0;' but We never execute this code because we have '#ifndef USB_ENABLE_TRANSFER_EVENT'. I think that this is the only problem that I have to finish the comunication but I don´t understand because the program no exits from DEMO_STATE_WAITINGS. Descent Pig And Hog Filesanywhere.

Norma Uni En Iso 19011 Pdf Free on this page. Hi, In my code I don´t have enable 'USB_ENABLE_TRANSFER_EVENT' I don´t know because is not enable, but, I enable this define and now the flags (gc_DevData.flags.txBusy and gc_DevData.flags.rxBusy) work perfectly. Now I can comunicate with the blood presure (at th LCD appears a digit of comunication similar at the conection with the PC) but the comunication is very dirty. Driver License Generator Texas more. When I send the comand to inicialize the system: 7 bytes out, all 0 7 bytes in, all 0 3 packets of 7 bytes out, all 0 1 packet of 2 bytes out, all 0 One packet in of success status message, otherwise repeat above two steps I have to recive a confirmation packet or repeat above two step.

The confirmation paket is: 0x02 0x4F 0x4B But I need to rpeat the above two steps 20 o 30 times. At the sniffer and with the PC this process repeats 2 o 3 times but with the PIC32 20 or 30 times. Next I send the paket: 0x56 0x45 0x52 0x30 0x30 (To get the version of the blood presure) The desire response is: 07 4F 4B 00 4D 37 30 38 07 30 49 54 20 32 30 37 01 4A 8C 4C 20 32 30 37 But I recive som data correct mixed with oters. I always recive the next packet: 07 4F 4B 4F 4B 30 49 54 07 4F 4B 4F 4B 30 49 54 07 20 4B 00 4D 54 20 32 07 30 37 4A 4D. I recive a paket but not corect.